Description
Belden 9244 010U500 Analog Video, RG59, #22 Solid BCCS, 85% BC Braid, PVC Jacket, CMX
22 AWG solid bare copper-covered steel conductor, polyehtylene insulation, bare copper braid shield (85% coverage), PVC jacket.
Ordering Details
- Manufacturer Part Number: 9244 010U500
- Color: Black
- Length: 500 ft
- Put-Up: UnReel
- UPC/EAN: 612825358817
Supplied as one 500 ft UnReel.
Construction Details
- RG Type: 59
- Series Type: 59
- Size: 22; Stranding: Solid; Nom. Diameter: 0.025 in; Material: BCCS - Bare Copper Covered Steel
- Material: PE - Polyethylene; Nom. Insulation Diameter: 0.146 in (3.71 mm)
- Outer Shield Type: Braid; Material: Bare Copper (BC); Coverage: 85%
- Material: PVC - Polyvinyl Chloride; Nom. Diameter: 0.242 in
Electrical Characteristics
- Frequency: 5-450 MHz; Min. Return Loss: 23 dB
- Frequency: 1 MHz; Nom. Attenuation: 0.6 dB/100ft
- Frequency: 10 MHz; Nom. Attenuation: 1.1 dB/100ft
- Frequency: 50 MHz; Nom. Attenuation: 2.4 dB/100ft
- Frequency: 100 MHz; Nom. Attenuation: 3.4 dB/100ft
- Frequency: 200 MHz; Nom. Attenuation: 4.9 dB/100ft
- Frequency: 400 MHz; Nom. Attenuation: 7 dB/100ft
- Frequency: 700 MHz; Nom. Attenuation: 9.7 dB/100ft
- Frequency: 900 MHz; Nom. Attenuation: 11.1 dB/100ft
- Frequency: 1000 MHz; Nom. Attenuation: 12 dB/100ft
- Frequency: 50 MHz; Max. Power Rating: 470 W
- Frequency: 100 MHz; Max. Power Rating: 310 W
- Frequency: 300 MHz; Max. Power Rating: 160 W
- Frequency: 500 MHz; Max. Power Rating: 115 W
- Frequency: 1,000 MHz; Max. Power Rating: 76 W
- Nom. Conductor DCR: 50 Ohm/1000ft (160 Ohm/km); Nom. Outer Shield DCR: 4.5 Ohm/1000ft (15 Ohm/km); Nom. Capacitance Cond-to-Shield: 19.4 pF/ft (63.6 pF/m); Nom. Characteristic Impedance: 75 Ohm; Nom. Velocity of Prop.: 66%
- UL Voltage Rating: 150 V RMS; Voltage Rating: 1700 V RMS
Mechanical Characteristics
- Operating: -40°C To +80°C
- Max. Pull Tension: 67 lbs (30 kg)
- Bulk Cable Weight: 33 lbs/1000ft (49 kg/km)
Standards and Compliance
- Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor
- Flammability / Reaction to Fire: VW-1, IEC 60332-1-2
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: CMX
- AWM Compliance: AWM 1354 (30 V 80°C)
- CEC / C(UL) Compliance: CMX
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
History
- Update and Revision: Revision Number: 0.379 Revision Date: 11-06-2026