Description
Belden 89207 010100 100Ω Twinax, 1 Pr #20 Str-1c TC/1c BC, FEP ins, FEP Inner Jkt, Duofoil®+TC Braid, FEP Jkt, CMP
Twinax 100Ω, 1 Pair, 20 AWG (7x28) one tinned, one bare copper conductor, FEP insulation, FEP inner jacket, Duofoil® + tinned copper braid shield 85%, FEP jacket, CMP
Ordering Details
- Manufacturer Part Number: 89207 010100
- Color: Black
- Length: 100 ft
- Put-Up: Reel
- UPC/EAN: 612825220756
- Manufacturer Footnote: C
Supplied as one 100 ft Reel.
Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.
Product Overview
- Suitable Applications: Computer, Instrumentation
Construction Details
- Size: 20 AWG; Stranding: 7x28; Nom. Diameter: 0.036 in; Material: TC - Tinned Copper
- Size: 20 AWG; Stranding: 7x28; Nom. Diameter: 0.036 in; Material: BC - Bare Copper
- Material: FEP - Fluorinated Ethylene Propylene; Nom. Insulation Diameter: 0.072 in (1.8 mm); Color Code: Clear; Notes: FEP on both conductors
- Material: FEP - Fluorinated Ethylene Propylene; Nom. Insulation Diameter: 0.201 in (5.11 mm); Color Code: Clear; Notes: FEP over pair
- Layer: 1; Outer Shield Type: Tape; Material: Tri-Laminate (Alum+Poly+Alum); Material Trade Name: Duofoil®; Coverage: 100%
- Layer: 2; Outer Shield Type: Braid; Material: Tinned Copper (TC); Coverage: 85%
- Material: FEP - Fluorinated Ethylene Propylene; Nom. Diameter: 0.259 in (6.58 mm)
- Overall Cable Diameter (Nominal): 0.259 in (6.58 mm)
Electrical Characteristics
- Frequency: 1 MHz; Nom. Attenuation: 0.30 dB/100m
- Frequency: 10 MHz; Nom. Attenuation: 1.20 dB/100m
- Frequency: 50 MHz; Nom. Attenuation: 2.80 dB/100m
- Frequency: 100 MHz; Nom. Attenuation: 4.10 dB/100m
- Frequency: 200 MHz; Nom. Attenuation: 6.40 dB/100m
- Frequency: 300 MHz; Nom. Attenuation: 8.40 dB/100m
- Frequency: 400 MHz; Nom. Attenuation: 10.20 dB/100m
- Nom. Conductor DCR: 9.5 Ohm/1000ft; Nom. Outer Shield DCR: 2.5 Ohm/1000ft (8.2 Ohm/km); Nom. Capacitance Cond-to-Shield: 23.0 pF/ft (75.5 pF/m); Nom. Characteristic Impedance: 100 Ohm; Nom. Velocity of Prop.: 70%
- UL Voltage Rating: 300 V (CMP)
Mechanical Characteristics
- UL Temperature: 200°C; Operating: -70°C to +200°C
- Installation Min.: 3.0 in (76 mm)
- Max. Pull Tension: 88 lbs (40 kg)
- Bulk Cable Weight: 52 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor - Plenum, Indoor
- Sustainability: CA Prop 65
- Flammability / Reaction to Fire: NFPA 262
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: CMP
- CEC / C(UL) Compliance: CMP
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
- Non-Plenum Number: 9207
History
- Update and Revision: Revision Number: 0.494 Revision Date: 02-20-2026
- Footnote: C - CRATE REEL PUT-UP.