Description
Belden 83804 0021000 Electronic, 4 C #12 Str TC, FEP Ins, OS+TC Brd, Red FEP Jkt, CMP FPLP
High Temperature Electronic, 4 Conductor 12AWG (7x20) Tinned Copper, FEP Insulation, Overall Beldfoil®+Tinned Copper Braid(85%) Shield, Red FEP Outer Jacket, CMP FPLP
Ordering Details
- Manufacturer Part Number: 83804 0021000
- Color: Red
- Length: 1,000 ft
- Put-Up: Reel
- UPC/EAN: 612825205784
- Manufacturer Footnote: C
Supplied as one 1,000 ft Reel.
Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.
Product Overview
- Suitable Applications: fire alarms; extreme high/low temperature environments; indoor/outdoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, …)
Construction Details
- Element: Conductor(s); No. of Elements: 4; Size: 12 AWG; Stranding: 7x20; Material: TC - Tinned Copper
- Element: Conductor(s); Material: FEP - Fluorinated Ethylene Propylene; Nom. Thickness: 0.016 in (0.41 mm); Nom. Insulation Diameter: 0.123 in (3.12 mm); Color Code: Black, White, Red, Green
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%
- Shield Type: Braid; Material: Tinned Copper (TC); Coverage: 85%
- Material: FEP - Fluorinated Ethylene Propylene; Nom. Thickness: 0.017 in (0.43 mm); Nom. Diameter: 0.365 in (9.27 mm)
- Overall Cable Diameter (Nominal): 0.365 in (9.27 mm)
Electrical Characteristics
- Element: Conductor(s); Nom. Conductor DCR: 1.74 Ohm/1000ft; Nom. Capacitance Cond-to-Cond: 32 pF/ft (100 pF/m); Nom. Capacitance Cond-to-Other (Conds + Shield): 55 pF/ft (180 pF/m); Max. Current: 22 Amps per Conductor at 25ºC
- Nom Outer Shield DCR: 3.2 Ohm/1000ft (10 Ohm/km)
- UL Voltage Rating: 300 V (CMP), 300 V (AWM 1424)
Mechanical Characteristics
- UL Temperature: 200°C; Operating: -70°C to +200°C
- Stationary Min.: 3.6 in (91 mm); Installation Min.: 3.6 in (91 mm)
- Max. Pull Tension: 406 lbs (184 kg)
- Bulk Cable Weight: 138 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor, Outdoor, Oil Resistance, Burial
- Sustainability: CA Prop 65
- Flammability / Reaction to Fire: NFPA 262 (UL 910), FT6
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: Article 760, Article 800
- CEC / C(UL) Compliance: CMP
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
Product Notes
- Notes: Gas Resistant
History
- Update and Revision: Revision Number: 0.527 Revision Date: 09-07-2025
- Footnote: C - CRATE REEL PUT-UP.