Description
Belden 82641 877U1000 RS232, #24-1pr, FEP, O/A Foil, LS-PVC Jkt, CMP
Computer EIA RS-232 Cable, 1-Pair, 24 AWG stranded (7x32) tinned copper conductors, FEP insulation, overall Beldfoil® shield (100% coverage), 24 AWG stranded tinned copper drain wire, Flamarrest® jacket, plenum rated
Ordering Details
- Manufacturer Part Number: 82641 877U1000
- Color: Natural
- Length: 1,000 ft
- Put-Up: UnReel
- UPC/EAN: 612825197492
Supplied as one 1,000 ft UnReel.
Product Overview
- Suitable Applications: indoor plenum applications; RS-232 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; panel wiring
Construction Details
- Element: Pair(s); No. of Elements: 1; Size: 24 AWG; Stranding: 7x32; Material: TC - Tinned Copper
- Element: Pair(s); Material: FEP - Fluorinated Ethylene Propylene; Nom. Thickness: 0.006 in (0.15 mm); Nom. Insulation Diameter: 0.036 in (0.91 mm); Color Code: Black & Red
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%; Drainwire Type: 24 AWG (7x32) TC
- Material: PVC - Polyvinyl Chloride; Nom. Thickness: 0.015 in (0.38 mm); Nom. Diameter: 0.108 in (2.74 mm)
- Overall Cable Diameter (Nominal): 0.108 in (2.74 mm)
Electrical Characteristics
- Element: Pair(s); Nom. Conductor DCR: 24.1 Ohm/1000ft; Nom. Capacitance Cond-to-Cond: 31 pF/ft (100 pF/m); Nom. Capacitance Cond-to-Other (Conds + Shield): 59 pF/ft (190 pF/m); Nom. Inductance: 0.17 µH/ft (0.56 µH/m); Max. Current: 2.2 Amps per Conductor at 25ºC
- Nom Outer Shield DCR: 28.8 Ohm/1000ft (94.5 Ohm/km)
- UL Voltage Rating: 300 V (CMP)
Mechanical Characteristics
- UL Temperature: 60°C; Operating: 0°C to +60°C
- Stationary Min.: 1.08 in (27.4 mm); Installation Min.: 1.08 in (27.4 mm)
- Max. Pull Tension: 16 lbs (7.3 kg)
- Bulk Cable Weight: 8 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor - Plenum, Indoor
- Sustainability: CA Prop 65
- Flammability / Reaction to Fire: NFPA 262, UL 910 (Plenum)
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: Article 800, CMP
- CEC / C(UL) Compliance: CMP
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
- Plenum Number: 88641
- Non-Plenum Number: 8641
History
- Update and Revision: Revision Number: 0.540 Revision Date: 09-07-2025
- Footnote: C - CRATE REEL PUT-UP.