Description
Belden 7810R 010500 50 Ohm Wireless Transmission Coax, RF 400, RG8, 10 AWG Solid BCCA, Foil + 95% TC Braid, PVC Jkt, CMR
50 Ohm Wireless Transmission Coax, RF 400, 10 AWG Solid Bare Copper Covered Aluminum, PE Insulation, Duobond® Foil + 95% Tinned Copper Braid Shield, PVC Jacket, CMR
Ordering Details
- Manufacturer Part Number: 7810R 010500
- Color: Black
- Length: 500 ft
- Put-Up: Reel
- UPC/EAN: 612825189824
- Manufacturer Footnote: C
Supplied as one 500 ft Reel.
Product Overview
- Suitable Applications: Point-to-point and point-to-multipoint wireless antenna communication; Wireless microphones, Two-Way Radios, Amateur (Ham) Radio, Low Power FM, GPS, RFID (Radio Frequency Identification)
Construction Details
- Element: Coax(es); No. of Elements: 1; Size: 10 AWG; Stranding: Solid; Nom. Diameter: 0.108 in; Material: BCCA - Bare Copper Covered Aluminum
- Material: PE - Polyethylene (Foam); Nom. Insulation Diameter: 0.285 in (7.24 mm); Color Code: White
- Insulation Table Notes: Gas Injected
- Layer: 1; Outer Shield Type: Tape; Material: Tri-Laminate (Alum+Poly+Alum); Material Trade Name: Duofoil®; Coverage: 100%
- Layer: 2; Outer Shield Type: Braid; Material: Tinned Copper (TC); Coverage: 95%
- Material: PVC - Polyvinyl Chloride; Nom. Diameter: 0.403 in (10.2 mm)
- Overall Cable Diameter (Nominal): 0.403 in (10.2 mm)
Electrical Characteristics
- Frequency: 5-6000 MHz; Max. VSWR: 1.25:1
- Frequency: 30 MHz; Nom. Attenuation: 0.7 dB/100ft; Max. Attenuation: 0.7 dB/100ft
- Frequency: 50 MHz; Nom. Attenuation: 0.9 dB/100ft; Max. Attenuation: 0.93 dB/100ft
- Frequency: 150 MHz; Nom. Attenuation: 1.5 dB/100ft; Max. Attenuation: 1.58 dB/100ft
- Frequency: 220 MHz; Nom. Attenuation: 1.8 dB/100ft; Max. Attenuation: 1.94 dB/100ft
- Frequency: 450 MHz; Nom. Attenuation: 2.7 dB/100ft; Max. Attenuation: 2.83 dB/100ft
- Frequency: 900 MHz; Nom. Attenuation: 3.8 dB/100ft; Max. Attenuation: 4.06 dB/100ft
- Frequency: 1500 MHz; Nom. Attenuation: 5.1 dB/100ft; Max. Attenuation: 5.32 dB/100ft
- Frequency: 1800 MHz; Nom. Attenuation: 5.6 dB/100ft; Max. Attenuation: 5.98 dB/100ft
- Frequency: 2000 MHz; Nom. Attenuation: 6 dB/100ft; Max. Attenuation: 6.35 dB/100ft
- Frequency: 2500 MHz; Nom. Attenuation: 6.7 dB/100ft; Max. Attenuation: 7.08 dB/100ft
- Frequency: 3000 MHz; Nom. Attenuation: 7.5 dB/100ft; Max. Attenuation: 7.97 dB/100ft
- Frequency: 3500 MHz; Nom. Attenuation: 8.2 dB/100ft; Max. Attenuation: 8.8 dB/100ft
- Frequency: 4500 MHz; Nom. Attenuation: 9.5 dB/100ft; Max. Attenuation: 10.23 dB/100ft
- Frequency: 5800 MHz; Nom. Attenuation: 11.1 dB/100ft; Max. Attenuation: 12 dB/100ft
- Frequency: 6000 MHz; Nom. Attenuation: 11.4 dB/100ft; Max. Attenuation: 12.23 dB/100ft
- Frequency: 30 MHz; Max. Power Rating: 3,427 W
- Frequency: 50 MHz; Max. Power Rating: 2,588 W
- Frequency: 150 MHz; Max. Power Rating: 1,428 W
- Frequency: 220 MHz; Max. Power Rating: 1,195 W
- Frequency: 450 MHz; Max. Power Rating: 817 W
- Frequency: 900 MHz; Max. Power Rating: 575 W
- Frequency: 1,500 MHz; Max. Power Rating: 437 W
- Frequency: 2,000 MHz; Max. Power Rating: 375 W
- Frequency: 2,500 MHz; Max. Power Rating: 334 W
- Frequency: 3,500 MHz; Max. Power Rating: 282 W
- Frequency: 4,500 MHz; Max. Power Rating: 247 W
- Frequency: 6,000 MHz; Max. Power Rating: 213 W
- Frequency: 4,500 MHz; Max. Power Rating: 247 W
- Frequency: 5,800 MHz; Max. Power Rating: 217 W
- Frequency: 6,000 MHz; Max. Power Rating: 213 W
- Nom. Conductor DCR: 1.34 Ohm/1000ft (4.40 Ohm/km); Nom. Outer Shield DCR: 2.0 Ohm/1000ft (6.6 Ohm/km); Nom. Capacitance Cond-to-Shield: 23 pF/ft (75 pF/m); Nom. Characteristic Impedance: 50 Ohm; Nom. Velocity of Prop.: 86%
- Voltage Rating: 300 V RMS
Mechanical Characteristics
- UL Temperature: 60°C; Operating: -40°C To +75°C
- Stationary Min.: 4.00 in (102 mm); Installation Min.: 4.00 in (102 mm)
- Max. Pull Tension: 150 lbs (68 kg)
- Bulk Cable Weight: 86 lbs/1000ft (130 kg/km)
Standards and Compliance
- Environmental Suitability: Indoor - Riser, Indoor
- Flammability / Reaction to Fire: UL 1666 Riser, FT4, IEC 60332-1-2
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: Article 800, CMR
- CEC / C(UL) Compliance: CMG
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
History
- Update and Revision: Revision Number: 0.623 Revision Date: 02-20-2026
- Footnote: C - CRATE REEL PUT-UP.