Description
Belden 1841A 0101000 DBS Cable, Dual RG6, 18 AWG BCCS, Foil + Braid, CM
Series 6 (RG6/U type Dual Coax), 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, Al. braid shield (60% coverage), PVC jacket.
Ordering Details
- Manufacturer Part Number: 1841A 0101000
- Color: Black
- Length: 1,000 ft
- Put-Up: Reel
- UPC/EAN: 612825124351
- Manufacturer Footnote: C
Supplied as one 1,000 ft Reel.
Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.
Manufacturer Status: Discontinued
Product Life Cycle
- Life Cycle: Discontinued - the product is no longer manufactured
- Discontinuation Announcement Date: 2024-07-08
Construction Details
- RG Type: 6
- Series Type: 6
- Size: 18; Stranding: Solid; Nom. Diameter: 0.04 in; Material: BCCS - Bare Copper Covered Steel
- Material: PE - Polyethylene (Foam); Nom. Insulation Diameter: 0.18 in (4.6 mm)
- Insulation Table Notes: Gas Injected
- Layer: 1; Outer Shield Type: Tape; Material: Tri-Laminate (Alum+Poly+Alum); Material Trade Name: Duofoil®; Coverage: 100%
- Layer: 2; Outer Shield Type: Braid; Material: Aluminum; Coverage: 60%
- Material: PVC - Polyvinyl Chloride; Nom. Diameter: 0.273 x 0.595 in
Electrical Characteristics
- Frequency: 950 - 2250 MHz; Min. Structural Return Loss: 15 dB
- Frequency: 2250 - 3000 MHz; Min. Structural Return Loss: 10 dB
- Frequency: 5 MHz; Nom. Attenuation: 0.5 dB/100ft; Max. Attenuation: 0.58 dB/100ft
- Frequency: 55 MHz; Nom. Attenuation: 1.4 dB/100ft; Max. Attenuation: 1.6 dB/100ft
- Frequency: 211 MHz; Nom. Attenuation: 2.6 dB/100ft; Max. Attenuation: 3.05 dB/100ft
- Frequency: 500 MHz; Nom. Attenuation: 4.1 dB/100ft; Max. Attenuation: 4.66 dB/100ft
- Frequency: 750 MHz; Nom. Attenuation: 5.1 dB/100ft; Max. Attenuation: 5.65 dB/100ft
- Frequency: 862 MHz; Nom. Attenuation: 5.5 dB/100ft; Max. Attenuation: 6.1 dB/100ft
- Frequency: 1000 MHz; Nom. Attenuation: 6 dB/100ft; Max. Attenuation: 6.55 dB/100ft
- Frequency: 1450 MHz; Nom. Attenuation: 7.8 dB/100ft; Max. Attenuation: 8 dB/100ft
- Frequency: 1800 MHz; Nom. Attenuation: 8.6 dB/100ft; Max. Attenuation: 8.8 dB/100ft
- Frequency: 2250 MHz; Nom. Attenuation: 9.8 dB/100ft; Max. Attenuation: 10 dB/100ft
- Frequency: 3000 MHz; Nom. Attenuation: 11.3 dB/100ft; Max. Attenuation: 11.9 dB/100ft
- Nom. Conductor DCR: 28 Ohm/1000ft (92 Ohm/km); Nom. Outer Shield DCR: 9 Ohm/1000ft (30 Ohm/km); Nom. Capacitance Cond-to-Shield: 16.2 pF/ft (53.1 pF/m); Nom. Characteristic Impedance: 75 Ohm; Nom. Velocity of Prop.: 83%
- Voltage Rating: 350 V RMS
Mechanical Characteristics
- Operating: -40°C To +80°C
- Max. Pull Tension: 252 lbs (114 kg)
- Bulk Cable Weight: 56 lbs/1000ft (83 kg/km)
Standards and Compliance
- Environmental Suitability: Indoor (Not Riser or Plenum), Indoor
- Flammability / Reaction to Fire: UL1685 UL Loading
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: CATV, CM
- CEC / C(UL) Compliance: CM
- European Directive Compliance: EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
History
- Update and Revision: Revision Number: 0.437 Revision Date: 07-30-2026
- Footnote: C - CRATE REEL PUT-UP.