null

Belden 1829P 8771000 Broadband Coax, Series 6, 18 AWG Solid BCCS, Foil + 60% AL Braid, Flamarrest® Jkt, CMP - Natural, 1,000 ft Reel

$1,509.99
SKU:
1829P 8771000
Shipping:
Calculated at Checkout
Color:
Natural
Length:
1,000 ft
Put-Up:
Reel
Manufacturer Status:
Active
Product Family:
1829P
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

Belden 1829P 8771000 Broadband Coax, Series 6, 18 AWG Solid BCCS, Foil + 60% AL Braid, Flamarrest® Jkt, CMP

Broadband Coax, Series 6, 18 AWG Solid Bare Copper Covered Steel Conductor, FEP Insulation, Foil + 60% Aluminum Braid Shield, Flamarrest® Jacket, CMP

Ordering Details

  • Manufacturer Part Number: 1829P 8771000
  • Color: Natural
  • Length: 1,000 ft
  • Put-Up: Reel
  • UPC/EAN: 612825124122

Supplied as one 1,000 ft Reel.

Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.

Product Overview

  • Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Direct Broadcast Satellite (DBS), Over-The-Air (OTA) antennas

Construction Details

  • Series Type: 6
  • Size: 18 AWG; Stranding: Solid; Nom. Diameter: 0.040 in; Material: BCCS - Bare Copper Covered Steel
  • Material: FEP - Fluorinated Ethylene Propylene (Foam); Nom. Insulation Diameter: 0.170 in (4.32 mm); Color Code: White
  • Layer: 1; Outer Shield Type: Tape; Material: Tri-Laminate (Alum+Poly+Alum); Material Trade Name: Duobond® II; Coverage: 100%
  • Layer: 2; Outer Shield Type: Braid; Material: Aluminum; Coverage: 60%
  • Material: PVC - Polyvinyl Chloride; Nom. Diameter: 0.235 in (5.97 mm)
  • Overall Cable Diameter (Nominal): 0.235 in (5.97 mm)

Electrical Characteristics

  • Frequency: 5 - 2500 MHz; Min. Structural Return Loss: 15 dB
  • Frequency: 2500 - 3000 MHz; Min. Structural Return Loss: 10 dB
  • Frequency: 1 MHz; Nom. Attenuation: 0.3 dB/100ft
  • Frequency: 10 MHz; Nom. Attenuation: 0.7 dB/100ft
  • Frequency: 50 MHz; Nom. Attenuation: 1.6 dB/100ft
  • Frequency: 100 MHz; Nom. Attenuation: 2.1 dB/100ft
  • Frequency: 200 MHz; Nom. Attenuation: 2.9 dB/100ft
  • Frequency: 400 MHz; Nom. Attenuation: 4.3 dB/100ft
  • Frequency: 700 MHz; Nom. Attenuation: 6.1 dB/100ft
  • Frequency: 750 MHz; Nom. Attenuation: 6.4 dB/100ft
  • Frequency: 900 MHz; Nom. Attenuation: 7.1 dB/100ft
  • Frequency: 1000 MHz; Nom. Attenuation: 7.6 dB/100ft
  • Frequency: 1450 MHz; Nom. Attenuation: 9.6 dB/100ft
  • Frequency: 1800 MHz; Nom. Attenuation: 11.0 dB/100ft
  • Frequency: 2250 MHz; Nom. Attenuation: 12.7 dB/100ft
  • Frequency: 3000 MHz; Nom. Attenuation: 15.1 dB/100ft
  • Nom. Conductor DCR: 28 Ohm/1000ft; Nom. Outer Shield DCR: 9 Ohm/1000ft (30 Ohm/km); Nom. Capacitance Cond-to-Shield: 16.3 pF/ft (53.5 pF/m); Nom. Characteristic Impedance: 75 Ohm; Nom. Velocity of Prop.: 83%
  • UL Voltage Rating: 300 V (CMP)

Mechanical Characteristics

  • Operating: -20°C to +75°C
  • Installation Min.: 2.4 in (61 mm)
  • Max. Pull Tension: 150 lbs (68 kg)
  • Bulk Cable Weight: 25 lbs/1000ft

Standards and Compliance

  • Environmental Suitability: Indoor - Plenum, Indoor
  • Sustainability: CA Prop 65
  • Flammability / Reaction to Fire: NFPA 262
  • CEC / C(UL) Compliance: CMP
  • European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
  • APAC Compliance: China RoHS II (GB/T 26572-2011)
  • Non-Plenum Number: 1829A

History

  • Update and Revision: Revision Number: 0.477 Revision Date: 02-20-2026

Resources

Belden 1829P Product Information