Description
Belden 1332A 0031000 Fieldbus, 20 Pr #18 Str TC, PO Ins, IS/OS, PVC Jkt, CMG
Fieldbus, 20 Pair 18AWG (7x26) Tinned Copper, PO Insulation, Individual & Overall Beldfoil® Shield, Orange PVC Outer Jacket, CMG
Ordering Details
- Manufacturer Part Number: 1332A 0031000
- Color: Orange
- Length: 1,000 ft
- Put-Up: Reel
- UPC/EAN: 612825112099
- Manufacturer Footnote: C
Supplied as one 1,000 ft Reel.
Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.
Product Overview
- Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
Construction Details
- Element: Pair(s); No. of Elements: 20; Size: 18; Stranding: 7x26; Material: TC - Tinned Copper
- Material: PP - Polypropylene; Color Code: Blue, Orange and Numbered
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%
- Material: Tinned Copper (TC)
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%
- Material: PVC - Polyvinyl Chloride; Nom. Diameter: 1.02 in; Ripcord: Yes
Electrical Characteristics
- Nom. Conductor DCR: 5.86 Ohm/1000ft (19.2 Ohm/km); Nom. Capacitance Cond-to-Shield: 45 pF/ft (150 pF/m); Max. Capacitance Unbalance: 1.2 pF/ft; Nom. Characteristic Impedence: 100 Ohm; Nom. Inductance: 0.19 µH/ft (0.62 µH/m); Nom. Velocity of Prop.: 66%; Max. Current: 5.2 Amps per Conductor
- Nom Outer Shield DCR: 4.9 Ohm/1000ft (16 Ohm/km)
- Nom. Insertion Loss (Attenuation) [dB/100ft]: 0.08
- UL Voltage Rating: 300 V RMS
Mechanical Characteristics
- UL Temperature: 105°C; Operating: -40°C to +105°C
- Max. Pull Tension: 1148 lbs (520.7 kg)
Standards and Compliance
- Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance, Oil Resistance
- Flammability / Reaction to Fire: UL1685 FT4 Loading, 1202, IEC 60332-3-24
- NEC / UL Compliance: Article 725, Article 727, Article 800, CMG, CMX-Outdoor, ITC, PLTC-ER
- CEC / C(UL) Compliance: CMG
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
History
- Update and Revision: Revision Number: 0.445 Revision Date: 02-20-2026
- Footnote: C - CRATE REEL PUT-UP.
Resources
- Technical Data Sheet
- Belden EN/IEC rated LSZH Classics/Electronics
- Belden GreenChoice LSZH-Jacketed Multi-conductor Cable
- Belden Classics Multi-conductor & Paired Cable
- Industrial Wire & Cable Solutions
- Belden SpaceMaker Series Electronic Wire Cable
- Belden SpaceMaker Series Electronic Cable EMEA
- RoHS Compliance Declaration