Description
Belden 1119A 010500 Inst, 1 Tri #16 Str BC, PVC-NYL Ins E2, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
UL Instrumentation, 1 Triad 16AWG (7x24) Bare Copper, PVC-NYL Insulation E2 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR
Ordering Details
- Manufacturer Part Number: 1119A 010500
- Color: Black
- Length: 500 ft
- Put-Up: Reel
- UPC/EAN: 612825107149
- Manufacturer Footnote: C Z
Supplied as one 500 ft Reel.
Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.
Product Overview
- Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …),RTD, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, actuators, positioners
Construction Details
- Element: Triad(s); No. of Elements: 1; Size: 16 AWG; Stranding: 7x24; Material: BC - Bare Copper
- Element: Triad(s); Material: PVC/Nylon - Polyvinyl Chloride + Nylon; Nom. Thickness: 0.022 in (0.56 mm); Nom. Insulation Diameter: 0.101 in (2.57 mm); Color Code: ICEA Chart E2
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%; Drainwire Type: 18 AWG (7x26) TC
- Material: PVC - Polyvinyl Chloride; Nom. Thickness: 0.047 in (1.2 mm); Nom. Diameter: 0.315 in (8.00 mm); Ripcord: Yes
- Overall Cable Diameter (Nominal): 0.315 in (8.00 mm)
Electrical Characteristics
- Element: Triad(s); Nom. Conductor DCR: 4.27 Ohm/1000ft; Max. Current: 18 Amps per conductor @ 30°C
- Nom Outer Shield DCR: 4.99 Ohm/1000ft (16.4 Ohm/km)
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF)
Mechanical Characteristics
- UL Temperature: 90°C Dry, 90°C Wet; Operating: -30°C to 90°C Dry/Wet
- Stationary Min.: 3.8 in (97 mm); Installation Min.: 3.8 in (97 mm)
- Max. Pull Tension: 129 lbs (58.5 kg)
- Bulk Cable Weight: 63 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
- Flammability / Reaction to Fire: UL 1685 FT4 Loading, FT4, T-29-520, IEEE 1202 FT4
- NEC / UL Compliance: Article 336, Article 760, NPLF, TC-ER
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- APAC Compliance: China RoHS II (GB/T 26572-2011)
History
- Update and Revision: Revision Number: 0.605 Revision Date: 04-10-2026
- Footnote: C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Resources
- Technical Data Sheet
- Belden CSA Tray-Rated VFD Cables
- MarineTuff Offshore & Marine Cable
- Industrial Wire & Cable Solutions
- UL 1277 Standard for Electrical Power & Control Tray Cables
- Series 9000 Gland Cross Reference
- UL Control Gland Cross Reference
- A Series Instrumentation Gland Cross Reference
- Basic Instrumentation Guide Gland Cross Reference
- RoHS Compliance Declaration