Belden 1073A 0102500 Inst, 16 Pr #16 Str BC, PVC-NYL Ins E1, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry/Wet
UL Instrumentation, 16 Pair 16AWG (7x24) Bare Copper, PVC-NYL Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry/Wet SUN RES DIR BUR
Ordering Details
- Manufacturer Part Number: 1073A 0102500
- Color: Black
- Length: 2,500 ft
- Put-Up: Reel
- UPC/EAN: 612825105831
- Manufacturer Footnote: C Z
Supplied as one 2,500 ft Reel.
Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.
Product Overview
- Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners
Construction Details
- Element: Pair(s); No. of Elements: 16; Size: 16 AWG; Stranding: 7x24; Material: BC - Bare Copper
- Element: Pair(s); Material: PVC/Nylon - Polyvinyl Chloride + Nylon; Nom. Thickness: 0.022 in (0.56 mm); Nom. Insulation Diameter: 0.101 in (2.57 mm); Color Code: Black, White and Numbered
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%; Drainwire Type: 16 AWG (7x24) TC
- Material: PVC - Polyvinyl Chloride; Nom. Thickness: 0.084 in (2.1 mm); Nom. Diameter: 0.928 in (23.6 mm); Ripcord: Yes
- Overall Cable Diameter (Nominal): 0.928 in (23.6 mm)
Electrical Characteristics
- Element: Pair(s); Nom. Conductor DCR: 3.67 Ohm/1000ft (12.0 Ohm/km)
- Nom Outer Shield DCR: 2.84 Ohm/1000ft (9.32 Ohm/km)
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF)
Mechanical Characteristics
- UL Temperature: 90°C Dry, 90°C Wet; Operating: -30C to 90C Dry, 75C wet
- Stationary Min.: 11.1 in (282 mm); Installation Min.: 11.1 in (282 mm)
- Max. Pull Tension: 1178 lbs (534.3 kg)
- Bulk Cable Weight: 510.3 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
- Flammability / Reaction to Fire: UL1685 (FT4 Loading), FT4, 1202
- NEC / UL Compliance: Article 336, Article 760, NPLF, TC-ER
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- APAC Compliance: China RoHS II (GB/T 26572-2011)
History
- Update and Revision: Revision Number: 0.567 Revision Date: 09-07-2025
- Footnote: C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Resources
- Technical Data Sheet
- Belden CSA Tray-Rated VFD Cables
- MarineTuff Offshore & Marine Cable
- Industrial Wire & Cable Solutions
- UL 1277 Standard for Electrical Power & Control Tray Cables
- Series 9000 Gland Cross Reference
- UL Control Gland Cross Reference
- A Series Instrumentation Gland Cross Reference
- Basic Instrumentation Guide Gland Cross Reference
- RoHS Compliance Declaration