Description
Belden 1066A 0105000 Inst, 12 Pr #18 Str BC, PVC-NYL Ins E1, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 75C Wet
UL Instrumentation, 12 Pair 18AWG (7x26) Bare Copper, PVC-NYL Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR
Ordering Details
- Manufacturer Part Number: 1066A 0105000
- Color: Black
- Length: 5,000 ft
- Put-Up: Reel
- UPC/EAN: 612825105695
- Manufacturer Footnote: C Z
Supplied as one 5,000 ft Reel.
Image is for illustration only. Actual cable color and packaging may vary. Refer to the listed color, length, and put-up for this part number.
Product Overview
- Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners
Construction Details
- Element: Pair(s); No. of Elements: 12; Size: 18 AWG; Stranding: 7x26; Material: BC - Bare Copper
- Element: Pair(s); Material: PVC/Nylon - Polyvinyl Chloride + Nylon; Nom. Thickness: 0.022 in (0.56 mm); Nom. Insulation Diameter: 0.088 in (2.2 mm); Color Code: Black and White and Numbered
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%; Drainwire Type: 18 AWG (7x26) TC
- Material: PVC - Polyvinyl Chloride; Nom. Thickness: 0.064 in (1.6 mm); Nom. Diameter: 0.717 in; Ripcord: Yes
- Overall Cable Diameter (Nominal): 0.717 in
Electrical Characteristics
- Nom. Conductor DCR: 6.6 Ohm/1000ft; Max. Current: 7 Amps per Conductor at 25ºC
- Nom Outer Shield DCR: 4.22 Ohm/1000ft (13.8 Ohm/km)
- UL Voltage Rating: 600 V (TC-ER), 150 V (NPLF)
Mechanical Characteristics
- UL Temperature: 90°C Dry, 90°C Wet; Operating: -20°C to +90°C
- Stationary Min.: 8.604 in (218.5 mm); Installation Min.: 8.604 in
- Max. Pull Tension: 560 lbs (250 kg)
- Bulk Cable Weight: 272 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Burial
- Flammability / Reaction to Fire: UL1685 UL Loading, IEEE 1202 FT4
- NEC / UL Compliance: Article 336, Article 760
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- APAC Compliance: China RoHS II (GB/T 26572-2011)
Product Notes
- Notes: Alternate color coding available upon request.
History
- Update and Revision: Revision Number: 0.417 Revision Date: 09-07-2025
- Footnote: C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Resources
- Technical Data Sheet
- Belden CSA Tray-Rated VFD Cables
- MarineTuff Offshore & Marine Cable
- Industrial Wire & Cable Solutions
- UL 1277 Standard for Electrical Power & Control Tray Cables
- Series 9000 Gland Cross Reference
- UL Control Gland Cross Reference
- A Series Instrumentation Gland Cross Reference
- Basic Instrumentation Guide Gland Cross Reference
- RoHS Compliance Declaration