Altronix AL300XPD16220 Power Supply Charger

$277.82
SKU:
AL300XPD16220
Shipping:
Calculated at Checkout

Product Overview

Power Supply Charger, 16 Fused Outputs, 12/24VDC @ 2.5A, 220VAC, BC400 Enclosure

AL300XPD16220 is a multi-output power supply/charger that converts a nominal 220VAC 50/60Hz input into sixteen (16) 12VDC or 24VDC outputs.

Input
Nominal 220VAC (working range 198VAC - 256VAC), 50/60Hz, 1.7A.
Input fuse rated @ 3.5A/250V.

Output
12VDC or 24VDC selectable output.
12VDC or 24VDC @ 2.5A supply current.
Sixteen (16) fuse protected outputs.
Outputs are rated @ 3.5A.
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.

Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.

Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery supervision (form "C" contacts).
Battery presence supervision (form "C" contacts).

Visual Indicators
AC input and DC output LED indicators.

Temperature
Operating 0 to 49° C (32 to 120° F ).
Storage - 20 to 70° C ( - 4 to 158° F).
Relative Humidity 85% +/- 5%
BTU/Hr. (approx.):
12VDC or 12VAC: 15 BTU/Hr.
24VDC or 24VAC: 30 BTU/Hr.
System AC input VA requirement: 374VA.

Power Supply Charger, 16 Fused Outputs, 12/24VDC @ 2.5A, 220VAC, BC400 Enclosure

AL300XPD16220 is a multi-output power supply/charger that converts a nominal 220VAC 50/60Hz input into sixteen (16) 12VDC or 24VDC outputs.

Input
Nominal 220VAC (working range 198VAC - 256VAC), 50/60Hz, 1.7A.
Input fuse rated @ 3.5A/250V.

Output
12VDC or 24VDC selectable output.
12VDC or 24VDC @ 2.5A supply current.
Sixteen (16) fuse protected outputs.
Outputs are rated @ 3.5A.
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.

Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.

Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery supervision (form "C" contacts).
Battery presence supervision (form "C" contacts).

Visual Indicators
AC input and DC output LED indicators.

Temperature
Operating 0 to 49° C (32 to 120° F ).
Storage - 20 to 70° C ( - 4 to 158° F).
Relative Humidity 85% +/- 5%
BTU/Hr. (approx.):
12VDC or 12VAC: 15 BTU/Hr.
24VDC or 24VAC: 30 BTU/Hr.
System AC input VA requirement: 374VA.