WIREGear Cat 5E CMR Enhanced 350 MHz UTP PVC 1000' Blue

$85.00
SKU:
CAT5E-CMR-U1000-BLUE
Shipping:
Calculated at Checkout

Specifications

Conductor Material – Solid Bare Copper 
Jacket Material – PVC 
Cable Length – 305 m | 1000 ft 
Diameter Over Jacket (±0.2mm) – 5.0 mm | 0.197 in 
Conductor Diameter – 0.483 mm | 0.019 in 
Insulation – Polyethylene (PE) 
Average Thickness (±0.03mm) – 0.21 mm | 0.008 in 
Min. Point Thickness – 0.2 mm | 0.007 in 
Insulation Dia. (±0.03mm) – 0.9 mm | 0.035 in 
Twisting Lay Length – 30 mm | 1.181 in 
Cabling Lay Length (±20mm) – 100 mm | 3.937 in 
Min. Point Thickness – 0.43 mm | 0.016 in 
Rip Cord – YES

Electrical Specifications

ANSI/TIA Category – 5E 
Transmission Standards – ANSI/TIA-568-C.2 | ISO/IEC 11801 Class D 
Reference Standard – YD/T1019-2001, UL Subject 444 
Product Standard Certification – UL File E340598
1.0-100.0MHz Impedance (ohms) – 100 ± 15
100-200MHz Impedance (ohms) – 100 ± 25
200-350MHz Impedance (ohms) – 100 ± 35
1.0-100.0MHz Delay Skew (ns/100m) – ≤45 
Pair-to-Ground Capacitance Unbalance (pF/100m) – ≤330
Max. Conductor DC Resistance 20 (ohms/km) – 93.8 
Resistance Unbalance (%) – ≤5
Installation Temperature – 0°C to +60°C (+32°F to +140°F) 
Operating Temperature – -20°C to +60°C (-4°F to +140°F)

General Specifications

Cable Type – U/UTP (unshielded) 
Pairs, quantity – 4 
Jacket Colors – Blue | White 
Conductor Gauge, singles – 24 AWG 
Conductor Type, singles – Solid 
Conductors, quantity – 8
RoHS 2002/95/EC – Compliant 
ISO 9001:2008
Fire Rating ETL Listed Type CMR 

Mechanical Characteristics

Test Object – Jacket 
Test Material – PVC 
Before Tensile Strength (Mpa) – ≥13.8 
Aging Elongation (%) – ≥100 
Aging Condition ( xhrs) – 100x240 
After Tensile Strength (Mpa) – ≥85% of unaged 
Aging Elongation (%) – ≥50% of unaged 
Cold Bend(-20±2 x4hrs) – No crack